1. Pay attention to the scope of application
When choosing laminated safety glass in buildings, you must pay attention to its scope of use, use safety glass in accordance with relevant national regulations, and ensure that the role of safety glass can be maximized. According to the requirements of the "Regulations on the Management of Safety Glass in Buildings", in construction, attention must be paid to the windows of buildings with 7 floors and above, curtain walls (except full glass curtains), floor panels used to withstand pedestrians, and public buildings. Laminated safety glass is used in entrances, exits, foyers, etc. It not only implements the safety principle, but also follows the economic principle.
Paying attention to the usage range of laminated safety glass can avoid waste, save materials, and use materials where they should be used, rather than placing them randomly without scope. At the same time, pay attention to the usage range of laminated safety glass and clarify the usage location to effectively avoid work errors. Paying attention to the scope of use is an important step in applying laminated safety glass in buildings. Accurate implementation of this step will help improve work efficiency and promote the project construction process.
2. All departments strictly implement relevant regulations
The "Management Regulations on Building Safety Glass" stipulates the parts of buildings that require the use of laminated safety glass. As a construction unit, it must strictly implement the specific regulations to ensure that the work is carried out in an orderly manner. In the process of implementing the regulations, the construction unit needs to consider long-term interests and cannot just start from the immediate interests. It cannot privately ask the design unit to design non-safety glass in the design plan, and cannot ask the construction unit to cut corners and install non-safety glass. Rather, it is necessary to strictly implement the relevant regulations, strictly grasp the design plan, implementation plan and work process, supervise the work of each department, and observe whether each department strictly implements the relevant regulations. The design unit itself should strengthen its sense of responsibility, design in strict accordance with the mandatory standards for engineering construction, and make its design indicators consistent with national regulations. The implementation unit plays an important role in the entire project, and they shoulder the heavy responsibility of inspection and audit.
Therefore, the construction unit needs to inspect each batch of laminated safety glass entering the site to detect its qualification and whether there are quality problems. It also needs to check whether each batch of laminated safety glass has a certification certificate and product certificate. After the inspection, you need to check whether the document is authentic. In addition to checking whether the quality of safety glass is up to standard, construction units also need to pay attention to their own work during the construction process. The work during the construction process includes the training of relevant personnel and the specific construction process. When training relevant personnel, the training content needs to include safety glass installation operations, and during the specific implementation process, relevant design plans and safety technical standards must be strictly implemented. In addition to the design unit and construction unit, the supervision unit and the production and supply unit also need to play their own roles.
The supervision unit needs to promptly supervise the preparations before construction and the specific construction process, and at the same time urge the construction unit to strictly install the approved design plan for construction. The most important thing for production and supply units is to assume social responsibilities, emphasize their own sense of responsibility, shoulder production and supply responsibilities, establish a sense of integrity, and provide relevant documents that can prove the quality of laminated safety glass, so as to ensure the orderliness of the basic work of building construction. conduct.
3. Give full play to the role of laminated safety glass
The prerequisite for giving full play to the role of laminated safety glass is that the construction department and design department need to master the characteristics of laminated safety glass. After rupture, the fragments will exist in the interlayer, which will minimize the harm to people. Therefore, the design department needs to design laminated safety glass on the surface of the building or in places prone to direct sunlight. In this way, not only can the aesthetic effect of safety glass be brought into play.The design department can gradually apply this advantage of laminated glass to residents' lives, allowing residents to use laminated safety glass when building their own houses to exert its sound insulation effect. And laminated safety glass can also be installed on school buildings to provide a quiet environment for students to study and people to live.
With the progress of society, economic development and the continuous improvement of people's living standards, how to reduce or eliminate safety hazards in buildings has become an issue of increasing concern. All departments need to work in strict accordance with the requirements of the "Regulations on the Management of Building Safety Glass", work together, unite and cooperate, and truly reduce the threat to people's safety caused by building glass.
After more than 20 years of upgrading, the machines produced by Fangding Technology Co., Ltd . have fully met customers' needs for laminated glass. Excellent vacuum and temperature control effects make the glass more transparent, with better adhesion and longer life.